PB21000PRT
Westinghouse - Trip Units And Programmers
PB21000PRT, Westinghouse, TRI-PAC, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 1000A, suitable for Tri-Pac PB,PA 1600A molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

HNB21200PRT
Westinghouse - Trip Units And Programmers
HNB21200PRT, Westinghouse, TRI-PAC, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 1200A, suitable for Tri-Pac 1200A- NB,HNB molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

TEPHM1
General Electric - Part And Accessory
TEPHM1, General Electric, TDM Model, circuit breaker accessory, Operating Handles, rotary level handle mechanism, handle included, door-mounted, handle mounting location right, handle to device connection 4-3/16 inch fixed depth shaft, shallow mount, NEMA 1/3R/12, suitable for use with TEB,TEC,TB1,TED,THED type molded case circuit breakers
From Get Price

HLA2125PT
Westinghouse - Trip Units And Programmers
HLA2125PT, Westinghouse, TRI-PAC, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 125A, suitable for 400A- LA,HLA Tri-Pac molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price

HLA2225PT
Westinghouse - Trip Units And Programmers
HLA2225PT, Westinghouse, TRI-PAC, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 225A, suitable for 400A- LA,HLA Tri-Pac molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price

PB31500T
Cutler Hammer - Trip Units And Programmers
PB31500T, Westinghouse, Cutler Hammer, Eaton, PB Series, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 1500A, suitable for PB 2500A molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

PAF21400T
Westinghouse - Trip Units And Programmers
PAF21400T, Westinghouse, PAF Series, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, front connected, rated for 1400A, suitable for PBF,PAF 2000A molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

PB2800PRT
Westinghouse - Trip Units And Programmers
PB2800PRT, Westinghouse, TRI-PAC, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 800A, suitable for Tri-Pac PB,PA 1600A molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

PA31600PRT
Westinghouse - Trip Units And Programmers
PA31600PRT, Westinghouse, TRI-PAC, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 1600A, suitable for Tri-Pac PB,PA 1600A molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

PAF2600T
Westinghouse - Trip Units And Programmers
PAF2600T, Westinghouse, PAF Series, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, front connected, rated for 600A, suitable for PBF,PAF 2000A molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

EZSGLL3604L4R
General Electric - Molded Case
EZSGLL3604L4R, General Electric, Spectra Series RMS main circuit breaker kit for EntellEon panelboards, type , requires 4X bus space, 3P, 3PH, 400A, 600V, 65kA@480V, UL listed, complete with MicroEntelliGuard trip unit with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and RELT, Solid State electronic, molded case circuit breakers
From Get Price

HLA2100PT
Westinghouse - Trip Units And Programmers
HLA2100PT, Westinghouse, TRI-PAC, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 100A, suitable for 400A- LA,HLA Tri-Pac molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price

PBF3900T
Westinghouse - Trip Units And Programmers
PBF3900T, Westinghouse, PBF Series, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, front connected, rated for 900A, suitable for PBF,PAF 2000A molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

PB21400PRT
Westinghouse - Trip Units And Programmers
PB21400PRT, Westinghouse, TRI-PAC, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 1400A, suitable for Tri-Pac PB,PA 1600A molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

HLA3600PT
Westinghouse - Trip Units And Programmers
HLA3600PT, Westinghouse, TRI-PAC, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 600A, suitable for 600A- LA,HLA Tri-Pac molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price

HNB31000PRT
Westinghouse - Trip Units And Programmers
HNB31000PRT, Westinghouse, TRI-PAC, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 1000A, suitable for Tri-Pac 1200A- NB,HNB molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

HNB3800PRT
Westinghouse - Trip Units And Programmers
HNB3800PRT, Westinghouse, TRI-PAC, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 800A, suitable for Tri-Pac 1200A- NB,HNB molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

EUSKTC3412L4R
General Electric - Molded Case
EUSKTC3412L4R, General Electric, Spectra Series RMS main circuit breaker kit for EntellEon panelboards, type , requires 6X bus space, 3P, 3PH, 1200A, 480V, 65kA@480V, UL listed, complete with MicroEntelliGuard trip unit with LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and RELT, Solid State electronic, molded case circuit breakers
From Get Price

JT305036
Cutler Hammer - Trip Units And Programmers
JT305036, Cutler Hammer, Series G, type JT, interchangeable Digitrip RMS 310 trip unit with LSIG, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, rated for 50A, suitable for Series G- JGE,JGS,JGH,JGC,JGU,JGX molded case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From Get Price

HNB2900PRT
Westinghouse - Trip Units And Programmers
HNB2900PRT, Westinghouse, TRI-PAC, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 900A, suitable for Tri-Pac 1200A- NB,HNB molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

ORPR16A100
Cutler Hammer - Rating Plug
ORPR16A100, Cutler Hammer, Series C, type ORPR, interchangeable rating plug element, fixed rated for 1000A, suitable for use with the 1600A current sensor rating, to be used with Series C- RD,RDC,CRD,CRDC molded case circuit breaker frame types, for use with DIGITRIP,OPTIM1050 solid state electronic trip units & circuit breakers
From Get Price

PAF22000T
Westinghouse - Trip Units And Programmers
PAF22000T, Westinghouse, PAF Series, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, front connected, rated for 2000A, suitable for PBF,PAF 2000A molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price

HLA2200PT
Westinghouse - Trip Units And Programmers
HLA2200PT, Westinghouse, TRI-PAC, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 200A, suitable for 400A- LA,HLA Tri-Pac molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price

HLA2250PT
Westinghouse - Trip Units And Programmers
HLA2250PT, Westinghouse, TRI-PAC, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 250A, suitable for 400A- LA,HLA Tri-Pac molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them