1. Home / 
  2. breaker

SORT BY
Limited Stock
PB31400PRT
PB31400PRT
Cutler Hammer - Trip Units And Programmers
PB31400PRT, Cutler Hammer, Eaton, Westinghouse, TRI-PAC, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 1400A, suitable for Tri-Pac PB,PA 1600A molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price
Limited Stock
FGRL4LL0400-7
FGRL4LL0400-7
General Electric - Rating Plug
FGRL4LL0400-7, General Electric, Record Plus, type , adjustable LT & LTD settable rating plug element for SMR2 trip units, 434584, rated for 400A, suitable for use with 4-pole FG 400A- FGN,FGH,FGL molded case circuit breaker frame types, for use with 4-pole SMR2 selective solid state electronic trip units & circuit breakers
From Get Price
Limited Stock
FGRL43NN0400-7
FGRL43NN0400-7
General Electric - Rating Plug
FGRL43NN0400-7, General Electric, Record Plus, type , adjustable LT & LTD settable rating plug element for SMR2 trip units, 434605, rated for 400A, suitable for use with 4-pole FG 630A- FGN,FGH,FGL molded case circuit breaker frame types, for use with 3-pole SMR2 selective solid state electronic trip units & circuit breakers
From Get Price
Limited Stock
MP08H-3P-125A-EO-BO-LIG
MP08H-3P-125A-EO-BO-LIG
Merlin Gerin - Insulated Case
MP08H-3P-125A-EO-BO-LIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 800A frame with 250A sensor rating and 125A rating plug, 3P, 3PH, 600V, 65kA@480V, available with STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP trip units, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
NB2900PRTV
NB2900PRTV
Westinghouse - Trip Units And Programmers
NB2900PRTV, Westinghouse, TRI-PAC, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 900A, 50°C, suitable for Tri-Pac 1200A- NB,HNB molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price
Limited Stock
EUSKTC3412L5R
EUSKTC3412L5R
General Electric - Molded Case
EUSKTC3412L5R, General Electric, Spectra Series RMS main circuit breaker kit for EntellEon panelboards, type , requires 6X bus space, 3P, 3PH, 1200A, 480V, 65kA@480V, UL listed, complete with MicroEntelliGuard trip unit with LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions and RELT, Solid State electronic, molded case circuit breakers
From Get Price
In Stock
30PC1800
30PC1800
Westinghouse - Rating Plug
30PC1800, Westinghouse, SELTRONIC, type , fixed rating plug element, rated for 1800A, suitable for use with 3000A Seltronic - PC,PCA,PCC,PCCA,PCG,PCGA,PCCG,PCCGA molded case circuit breaker frame types, for use with Seltronic solid state electronic trip units & circuit breakers; these rating plugs are obsolete; however we do still stock them
From $481.76
Limited Stock
ORPK125A70
ORPK125A70
Cutler Hammer - Rating Plug
ORPK125A70, Cutler Hammer, Series C, type ORPK, interchangeable rating plug element, rated for 70A, suitable for use with the 125A current sensor rating, to be used with Series C- KD,DK,KDB,HKD,HKDB,KDC,CKD,CHKD molded case circuit breaker frame types, for use with DIGITRIPOPTIM550,DIGITRIPOPTIM1050 solid state electronic trip units & circuit breakers
From Get Price
Limited Stock
TMQV22225
TMQV22225
General Electric - Molded Case
TMQV22225, General Electric, Mini Mod III, type branch circuit breaker, 1PH, 2P, 240V, 225A, 100kA@240V, very high interrupting capacity, Bolt-On, complete with mounting hardware for residential meter stacks, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case circuit breakers; for use with GE Meter Stacks 200A and 225A sockets
From Get Price
Limited Stock
FGRL3NN0400-7
FGRL3NN0400-7
General Electric - Rating Plug
FGRL3NN0400-7, General Electric, Record Plus, type , adjustable LT & LTD settable rating plug element for SMR2 trip units, 436726, rated for 400A, suitable for use with 3-pole FG 630A- FGN,FGH,FGL molded case circuit breaker frame types, for use with 3-pole SMR2 selective solid state electronic trip units & circuit breakers
From Get Price
Limited Stock
MICROLOGIC-7.0H
MICROLOGIC-7.0H
Merlin Gerin - Trip Units And Programmers
MICROLOGIC-7.0H, Merlin Gerin, Micrologic, field installable, 47295, Micrologic standard 7.0H trip unit with earth leakage, LSI - Long-Time, Short-Time and Instantaneous trip functions and harmonic meter, digital display with multiple adjustable settings, suitable for Compact & Masterpact - NS,NT,NW molded case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From Get Price
Limited Stock
434622
434622
General Electric - Rating Plug
434622, General Electric, Record Plus, type , adjustable LT & LTD settable rating plug element for SMR2 trip units, FGRL43NN0630-7, rated for 630A, suitable for use with 4-pole FG 630A- FGN,FGH,FGL molded case circuit breaker frame types, for use with 3-pole SMR2 selective solid state electronic trip units & circuit breakers
From Get Price
Limited Stock
MD4CSN
MD4CSN
Cutler Hammer - Cubicles (Cradles)
MD4CSN, Cutler Hammer, Magnum DS, circuit breaker accessories, cubicles (cradles), cassette cell switch field option kit, 4 Form C contacts, includes the switch, mounting bracket and hardware, for easy field installation to cassette cell secondary terminal blocks, suitable for use with drawout cassettes and narrow frame type MDN low voltage power insulated case circuit breakers
From Get Price
Limited Stock
436738
436738
General Electric - Rating Plug
436738, General Electric, Record Plus, type , adjustable LT & LTD settable rating plug element for SMR2 trip units, FGRL3NN0500-7, rated for 500A, suitable for use with 3-pole FG 630A- FGN,FGH,FGL molded case circuit breaker frame types, for use with 3-pole SMR2 selective solid state electronic trip units & circuit breakers
From Get Price
In Stock
TMQV22125MM
TMQV22125MM
General Electric - Molded Case
TMQV22125MM, General Electric, Mini Mod III, type main circuit breaker, 1PH, 2P, 240V, 125A, 100kA@240V, very high interrupting capacity, Bolt-On, complete with mounting hardware for residential meter stacks, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, molded case circuit breakers; for use with GE Meter Stacks 200A and 225A sockets
From $637.99
Limited Stock
S33685
S33685
Schneider Electric - Under Voltage Release
S33685, Square D, Schneider Electric, PowerPact, under voltage release, (1) externally mounted non-adjustable time delay unit, 200/250Vac/Vdc; M, P & R frame kit includes time delay module only, circuit breaker suffix code KC; suitable for use with MG,MJ,PG,PJ,PK,PL,RG,RJ,RK,RL frame molded case circuit breakers
From Get Price
In Stock
33525
33525
Merlin Gerin - Trip Units And Programmers
33525, Square D, Schneider Electric, Merlin Gerin, Micrologic, field installable Micrologic standard 2.0A trip unit, IEC only, with LS - Long-Time and Short-Time trip functions, suitable for NS,NT,NW,PG,PJ,PK,PL,RG,RJ,RK,RL molded case & insulated case circuit breaker frame types, Solid State electronic trip units & circuit breakers
From $23.19
Limited Stock
A6LCG600
A6LCG600
Westinghouse - Rating Plug
A6LCG600, Westinghouse, SELTRONIC, type , adjustable rating plug element, rated for 600A, suitable for use with 600A Seltronic - LCG,LCGA,HLCG,HLCGA,LCCG,LCCGA,HLCCG,HLCCGA molded case circuit breaker frame types, for use with Seltronic solid state electronic trip units & circuit breakers; these rating plugs are obsolete; however we do still stock them
From Get Price
Limited Stock
PB33000PT
PB33000PT
Cutler Hammer - Trip Units And Programmers
PB33000PT, Eaton, Westinghouse, Cutler Hammer, TRI-PAC, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 3000A, suitable for Tri-Pac PB,PA 3000A molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price
Limited Stock
HNB26000TM
HNB26000TM
Westinghouse - Trip Units And Programmers
HNB26000TM, Westinghouse, MARK 75, type , interchangeable trip unit with I - Instantaneous trip functions, front adjustable, rated for 1200A, suitable for NB,HNB,NBY 1200A molded case circuit breaker frame types, magnetic trip range 3000-6000A, Magnetic Only trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price
Limited Stock
RP6R20A125
RP6R20A125
Cutler Hammer - Rating Plug
RP6R20A125, Cutler Hammer, Series C, type , interchangeable rating plug element, fixed rated for 1250A, suitable for use with the 2000A current sensor rating, to be used with IEC rated Series C - RW,RWC molded case circuit breaker frame types, for use with DIGITRIP,RMS510,RMS610,RMS810,RMS910 solid state electronic trip units & circuit breakers
From Get Price
Limited Stock
A3LC275
A3LC275
Westinghouse - Rating Plug
A3LC275, Westinghouse, SELTRONIC, type , adjustable rating plug element, rated for 275A, suitable for use with 300A Seltronic - LC,LCA,LCG,LCGA,HLC,HLCA,HLCG,HLCGA molded case circuit breaker frame types, for use with Seltronic solid state electronic trip units & circuit breakers; these rating plugs are obsolete; however we do still stock them
From Get Price
Limited Stock
MP25H2-3P-2500A
MP25H2-3P-2500A
Merlin Gerin - Insulated Case
MP25H2-3P-2500A, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 2500A frame, includes 2500A sensor rating with 2500A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
HLB23000TM
HLB23000TM
Westinghouse - Trip Units And Programmers
HLB23000TM, Westinghouse, MARK 75, type , interchangeable trip unit with I - Instantaneous trip functions, rated for 400A, front adjustable, suitable for 400A- LB,HLB molded case circuit breaker frame types, magnetic trip range 1500-3000A, Magnetic Only trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price