


- Home /
15 amp breaker
916,382 Results
Refine Results
In Stock
Subcategory
SORT BY

MDN4083LEA0122NMNC4NNYMPX
Cutler Hammer - Insulated Case
MDN4083LEA0122NMNC4NNYMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 100A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

MDN4083LEA0822NMNK2NNHNCX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNK2NNHNCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 600Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Ronis key interlock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

MDN4083LEA0422NMNH2YNYCWX
Cutler Hammer - Insulated Case
MDN4083LEA0422NMNH2YNYCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 400A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

MDN4083LEA0822NMNF2NNKNPX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNF2NNKNPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price

EEJD240100SB2
Cutler Hammer - Mounting Hardware
EEJD240100SB2, Cutler Hammer, EE Series, mounting hardware, plug-in mounting module, rated for 100A, AC phase connection, 480V max, Copper, Single Branch mounting style, suitable for use with ED,EDH,EDC,JD,HJD,JDC circuit breaker frames and EP panelboards; these modules are obsolete, however we still stock them
From Get Price

PGA36120CU73AE1RE10
Schneider Electric - Molded Case
PGA36120CU73AE1RE10, Schneider Electric, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 1200A, 600V, 35kA@480V, UL listed, standard interrupting capacity, I-Line Style Plug-In, 100% rated, complete with door mounted standard black handle, micrologic interchangeable harmonic 5.0H trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, molded case circuit breakers
From Get Price

MDN4083LEA0622NMNENYNRCWX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNENYNRCWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 110-125Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price

JRA36000S17
Schneider Electric - Molded Case
JRA36000S17, Square D, Schneider Electric, PowerPact, type , ABC phase connection, 3P, 3PH, 175A, 600V, 200kA@480V, current limiting, I-Line Style Plug-In, UL listed, NA - No Overcurrent Protection, with non-interchangeable trip unit, Non-Automatic molded case switch, molded case circuit breakers
From Get Price

SEF363000LSIET2
Schneider Electric - Insulated Case
SEF363000LSIET2, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 3000A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 24VDC spring charging motor, shunt closing coil & shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

SEF361800LSIES9A4
Square D - Insulated Case
SEF361800LSIES9A4, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 1800A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & 24VDC shunt trip along with 2A2B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

SEF363200LSIGES7
Square D - Insulated Case
SEF363200LSIGES7, Schneider Electric, Square D, SE Series, type , 3P, 3PH, 3200A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, 120VAC shunt closing coil & 125VDC shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

MDN4083LEA0822NMNH4YCNDCX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNH4YCNDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame with factory installed block close PB metal frame padlockable pushbutton cover, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, load side lug terminals, 4A/4B auxiliary switch, mechanical trip indicator, OTS switch & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

SHB4G6N9P
General Electric - Insulated Case
SHB4G6N9P, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Bolt-On, back connected, 2500A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, current metering, modbus communcation & ZSI features and 800A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

MPA31F0804242
General Electric - Air
MPA31F0804242, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, 220/250V dc/ac motor operator, 48V dc closing coil, 220/250V dc/ac shunt trip and 110/130V ac undervoltage trip, 3P, 3PH, 800A, 690V, 50kA@415V, Bolt-On, NA - No Overcurrent Protection, Non-Automatic switch, air circuit breakers
From Get Price

MN324UA
Cutler Hammer - Cubicles (Cradles)
MN324UA, Cutler Hammer, Magnum DS, cubicles (cradles), universal cassettes for drawout circuit breakers, cassette standard features include an arc hood, provisions for secondary terminal blocks including wiring, and a cell rejection kit, suitable for standard Magnum DS 4-pole 2500-3200A MDS frame low voltage air circuit breakers
From Get Price

MPA42F40W4450
General Electric - Insulated Case
MPA42F40W4450, General Electric, M-PACT, type , frame size 2, manually operated, 5 N.O- 3 N.C. Auxiliary switches, Mpro-50H trip unit, 220/250V dc/ac motor operator, 220/250V dc/ac closing coil and 380/400V ac shunt trip, 4P, 3PH, 4000A, 690V, 50kA@415V, fixed/Bolt-On, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State electronic, insulated case circuit breakers
From Get Price

MDN4083LEA0222NMNH2ENYDCX
Cutler Hammer - Insulated Case
MDN4083LEA0222NMNH2ENYDCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 200A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 48Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, operations counter, Kirk key interlock, load side lug terminals & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price

PLM34060CU44ABD
Square D - Molded Case
PLM34060CU44ABD, Schneider Electric, Square D, PowerPact, type , 3P, 3PH, 600A, 480V, 100kA@480V, UL listed, extra high interrupting capacity, Bolt-On, 100% rated, complete with 1A/1B overcurrent trip switch, micrologic interchangeable ammeter 6.0A trip, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions and line side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price

SSD4G6A4M
General Electric - Insulated Case
SSD4G6A4M, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LSIGA - Long-Time, Short-Time, Instantaneous and Ground Fault Alarm trip functions, current metering & RELT features and 750A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

SHD1G357L
General Electric - Insulated Case
SHD1G357L, General Electric, Power Break II, type , 3P, 3PH, 600V, 800A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 800A frame rating, complete with Entelliguard trip, LSHG - Long-Time, Short-Time, High-Range Instantaneous and Ground Fault trip functions, full metering, RELT, modbus communication & ZSI features and 700A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

SSF5G8A22
General Electric - Insulated Case
SSF5G8A22, General Electric, Power Break II, type , 3P, 3PH, 600V, 3000A current sensor rating, 100kA@480V, standard interrupting capacity, Bolt-On, front connected, 3000A frame rating, complete with Entelliguard trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, current metering & RELT features and 3000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price

SEHD36400LSGES1E5
Schneider Electric - Insulated Case
SEHD36400LSGES1E5, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 400A, 600V, 150kA@480V, high interrupt rating, Draw-Out, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 120VAC spring charging motor, shunt closing coil & shunt trip along with AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

SEF362000LIES2D5
Square D - Insulated Case
SEF362000LIES2D5, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 2000A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LI - Long-Time and Instantaneous trip functions, Solid State protection, electrically operated complete with 24VDC spring charging motor, shunt closing coil & shunt trip along with AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price

SHD3G6Z8W
General Electric - Insulated Case
SHD3G6Z8W, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 100kA@480V, high interrupting capacity, Draw-Out, 2000A frame rating, complete with Entelliguard trip, LIG - Long-Time, Instantaneous and Ground Fault trip functions, current metering & ZSI features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price