1. Home / 
  2. 15 amp breaker

SORT BY
In Stock
HDA261001BHSH
HDA261001BHSH
Square D - Molded Case
HDA261001BHSH, Square D, PowerPact, type , 2P, A & B phase connection, 1PH, 100A, 600V, 18kA@480V, UL listed, standard interrupting capacity, I-Line Style Plug-In, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and load side lug terminals, Thermal Magnetic, complete with alarm switch low-level, 380/480 VAC shunt trip, molded case circuit breakers
From $1,706.25
Limited Stock
MPA41F20N4330
MPA41F20N4330
General Electric - Insulated Case
MPA41F20N4330, General Electric, M-PACT, type , frame size 1, manually operated, with 5 N.O.-3 N.C. Auxiliary switches, Mpro-27 trip unit, 220/250V dc/ac motor operator, 110/130V dc/ac closing coil and 110/130V dc/ac shunt trip, 4P, 3PH, 2000A, 690V, 50kA@415V, Bolt-On, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
TPMM5616M
TPMM5616M
General Electric - Insulated Case
TPMM5616M, General Electric, Power Break I, type , 3P, 3PH, 600V, 1600A current sensor rating, 1600A frame rating, 65kA@480V, 100% equipment rated, stationary, not UL listed, standard interrupting capacity, Bolt-On, for use with non-interchangeable MagneTrip programmer, I - Instantaneous trip function, Solid State, insulated case circuit breakers; these breakers are obsolete, however we do still stock them
From Get Price
Limited Stock
SSD4G6K9W
SSD4G6K9W
General Electric - Insulated Case
SSD4G6K9W, General Electric, Power Break II, type , 3P, 3PH, 600V, 2000A current sensor rating, 65kA@480V, standard interrupting capacity, Draw-Out, 2500A frame rating, complete with Entelliguard trip, LIGA - Long-Time, Instantaneous and Ground Fault Alarm trip functions, current metering & ZSI features and 2000A rating plug, Solid State electronic, insulated case circuit breakers, suitable for use with Power Break II switchgear systems
From Get Price
Limited Stock
E2K3400MJWS49
E2K3400MJWS49
Westinghouse - Molded Case
E2K3400MJWS49, Eaton, Westinghouse, Cutler Hammer, Series C, E2 mining service breakers, type , 3P, 3PH, 400A, 600V, 250Vdc, 25kA@600V, standard interrupting capacity, Bolt-On, complete with mag only trip, left-pole mounted 48-60Vac or Vdc 50/60Hz, left side mount shunt trip, I - Instantaneous protection only, magnetic range 875-1750A lugs not included, MCP, motor circuit protectors, Magnetic Only, molded case circuit breakers
From Get Price
Limited Stock
NE234150SE3
NE234150SE3
American - Molded Case
NE234150SE3, American, Federal Pacific, NE Series, type , 3P, 3PH, 150A, 240V, 18kA@240V, standard interrupting capacity, Bolt-On, complete with 120V shunt trip, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, and load side lug terminals, Thermal Magnetic, molded case circuit breakers; these breakers are obsolete; however, we do still stock them
From Get Price
In Stock
HGL26125AASN
HGL26125AASN
Square D - Molded Case
HGL26125AASN, Square D, PowerPact, type , 2P, 1PH, 125A, 600V, 35kA@480V, high interrupting capacity, Feed-Thru, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, complete with 1A/1B aux switch, 12 VDC shunt trip, molded case circuit breakers
From $1,919.19
Limited Stock
SEHF363000LSIGES4A8
SEHF363000LSIGES4A8
Schneider Electric - Insulated Case
SEHF363000LSIGES4A8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 3000A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & shunt trip along with 4A4B with 1N.O./N.C. AC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
In Stock
HDL26050YP
HDL26050YP
Square D - Molded Case
HDL26050YP, Square D, PowerPact, type , 2P, 1PH, 50A, 600V, 18kA@480V, standard interrupting capacity, Feed-Thru, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions and line & load side lug terminals, Thermal Magnetic, complete with "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $553.64
In Stock
HDA36060AABH
HDA36060AABH
Square D - Molded Case
HDA36060AABH, Square D, PowerPact, type , 3PH, 3P, ABC phase connection, 60A, 600V, 18kA@480V, standard interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, complete with 1A/1B aux switch, alarm switch low-level, molded case circuit breakers
From $1,322.83
Limited Stock
EGH3080FFGVH08
EGH3080FFGVH08
Cutler Hammer - Molded Case
EGH3080FFGVH08, Cutler Hammer, Series G, type , 3P, 3PH, 80A, 600V, 65kA@480V, high interrupting capacity, for Marine applications 50°C, not UL listed, Feed-Thru, complete with non-interchangeable trip unit and line & load side lug terminals, Thermal Magnetic, molded case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0822NMNF2NNCNAX
MDN4083LEA0822NMNF2NNCNAX
Cutler Hammer - Insulated Case
MDN4083LEA0822NMNF2NNCNAX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 800A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals & mechanical trip indicator, Solid State, low voltage power insulated case circuit breakers
From Get Price
Limited Stock
MDN4083LEA0622NMNR2ENKMCX
MDN4083LEA0622NMNR2ENKMCX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNR2ENKMCX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 208-240Vac UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Kirk keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, unwired
From Get Price
Limited Stock
PJP36060U73AE1BD
PJP36060U73AE1BD
Schneider Electric - Molded Case
PJP36060U73AE1BD, Square D, Schneider Electric, PowerPact, type , 3P, 3PH, 600A, 600V, 65kA@480V, UL listed, high interrupting capacity, Bolt-On, complete with 1A/1B overcurrent trip switch, micrologic interchangeable harmonic 5.0H trip, LSI - Long-Time, Short-Time and Instantaneous trip functions and load side lug terminals, Solid State electronic, molded case circuit breakers
From Get Price
Limited Stock
SEF36600LSGES4F4
SEF36600LSGES4F4
Square D - Insulated Case
SEF36600LSGES4F4, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 600A, 600V, 100kA@480V, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.C. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
SEHF36350LSIGET2
SEHF36350LSIGET2
Square D - Insulated Case
SEHF36350LSIGET2, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 350A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 24VDC spring charging motor, shunt closing coil & shunt trip, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0622NMNC4YNRMPX
MDN4083LEA0622NMNC4YNRMPX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNC4YNRMPX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 24Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Ronis keylock, load side lug terminals, mechanical trip indicator & OTS switch, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, without shutters, pre-wired
From Get Price
Limited Stock
LGC360039G
LGC360039G
Cutler Hammer - Molded Case
LGC360039G, Cutler Hammer, Series G, type , 3P, 3PH, 600A, 600V, 100kA@480V, current limiting, Feed-Thru, complete with interchangeable trip, ALSIG - Arcflash Reduction, Long-Time, Short-Time, Instantaneous and Ground Fault trip functions with arcflash reduction maintenance system and line & load side lug terminals, Solid State electronic molded case circuit breakers
From Get Price
Limited Stock
SEHF361800LSGES4E8
SEHF361800LSGES4E8
Square D - Insulated Case
SEHF361800LSGES4E8, Square D, Schneider Electric, SE Series, type , 3P, 3PH, 1800A, 600V, 150kA@480V, high interrupt rating, Bolt-On, complete with Micrologic Series B trip device, LSIG - Long-Time, Short-Time, Instantaneous and Ground Fault trip functions, Solid State protection, electrically operated complete with 125VDC spring charging motor, shunt closing coil & shunt trip along with 2 N.O. AC/DC rated auxiliary switch with bell alarm, insulated case circuit breakers, these breakers are now obsolete; however, we do still stock them
From Get Price
Limited Stock
MDN4083LEA0622NMNF4NNCDSX
MDN4083LEA0622NMNF4NNCDSX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNF4NNCDSX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 4A/4B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, mechanical trip indicator & latch check switch for external wiring, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, unwired
From Get Price
In Stock
HGA36100U43XAFBHSJYP
HGA36100U43XAFBHSJYP
Square D - Molded Case
HGA36100U43XAFBHSJYP, Square D, PowerPact, type , 3P, ABC phase connection, 3PH, 100A, 600V, 35kA@480V, high interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse connection, micrologic ammeter 5.2A non-interchangeable trip, LSI - Long-Time, Short-Time and Instantaneous trip functions, Solid State electronic, complete with 2A/2B low-level aux switch, alarm switch low-level, 525/600 VAC shunt trip, "ON" or "OFF" end handle padlock device, molded case circuit breakers
From $2,344.65
Limited Stock
E2J3250TMC
E2J3250TMC
Cutler Hammer - Trip Units And Programmers
E2J3250TMC, Cutler Hammer, Series C, type , 3P, interchangeable trip, I - Instantaneous trip function, rated for 250A, magnetic trip range 450-900A, suitable for 250A- E2J,E2JM mining service Magnetic Only molded case circuit breaker frame types, Magnetic Only trip units & circuit breakers
From Get Price
In Stock
HGA36050BKUP
HGA36050BKUP
Square D - Molded Case
HGA36050BKUP, Square D, PowerPact, type , 3PH, 3P, ABC phase connection, 50A, 600V, 35kA@480V, high interrupting capacity, I-Line Style Plug-In, UL listed, suitable for reverse fed applications, non-interchangeable trip, LI - Long-Time and Instantaneous trip functions, Thermal Magnetic, complete with alarm switch and overcurrent trip switch, low-level, 48 VDC under voltage release (UVR), molded case circuit breakers
From $1,543.50
Limited Stock
MDN4083LEA0622NMNF2ENCMWX
MDN4083LEA0622NMNF2ENCMWX
Cutler Hammer - Insulated Case
MDN4083LEA0622NMNF2ENCMWX, Cutler Hammer, Magnum DS, type , drawout mounted, narrow frame, 3P, 3PH, 800A, 600A current sensors and rating plugs, 600V, 42kA@600V, 40°C, Bolt-On, manually operated, complete with factory installed 220-250Vdc UVR, 2A/2B auxiliary switch, interchangeable Digitrip 220, LI - Long-Time and Instantaneous trip functions, Castell keylock, load side lug terminals, Solid State, low voltage power insulated case circuit breakers, shipped in drawout narrow cassettes, with shutters, pre-wired
From Get Price