1. Home / 
  2. breaker

SORT BY
In Stock
LB2400T
LB2400T
Westinghouse - Trip Units And Programmers
LB2400T, Westinghouse, AB DE-ION, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 400A, suitable for 400A- LB,HLB standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From $567.47
Limited Stock
MP12-3P-1200A-EO-DO-LIG
MP12-3P-1200A-EO-DO-LIG
Merlin Gerin - Insulated Case
MP12-3P-1200A-EO-DO-LIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1200A frame with 1200A sensor rating with 1200A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
LA3070TA
LA3070TA
Westinghouse - Trip Units And Programmers
LA3070TA, Westinghouse, LA Series, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 70A, 50°C, suitable for 400A- LA,HLA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete, however we do still stock them
From Get Price
Limited Stock
MP40H-3P-4000A-MO-BO-LSG
MP40H-3P-4000A-MO-BO-LSG
Merlin Gerin - Insulated Case
MP40H-3P-4000A-MO-BO-LSG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 4000A frame, includes 4000A sensor rating with 4000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
HMA3150TV
HMA3150TV
Westinghouse - Trip Units And Programmers
HMA3150TV, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 150A, 50°C, suitable for 800A- MA,HMA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price
Limited Stock
HMA2250TV
HMA2250TV
Westinghouse - Trip Units And Programmers
HMA2250TV, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 250A, 50°C, suitable for 800A- MA,HMA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price
Limited Stock
PB25000TM
PB25000TM
Westinghouse - Trip Units And Programmers
PB25000TM, Westinghouse, PB Series, type , interchangeable trip unit with I - Instantaneous trip functions, front adjustable, rear connected, rated for 2000A, suitable for PB,PA 2500A molded case circuit breaker frame types, magnetic trip range 1500-5000A, Magnetic Only trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price
Limited Stock
PBF37000TM
PBF37000TM
Westinghouse - Trip Units And Programmers
PBF37000TM, Westinghouse, PBF Series, type , interchangeable trip unit with I - Instantaneous trip functions, front adjustable, front connected, rated for 2000A, suitable for PBF,PAF 2500A molded case circuit breaker frame types, magnetic trip range 2500-7000A, Magnetic Only trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price
Limited Stock
MP32H-3P-3200A-EO-BO-LS
MP32H-3P-3200A-EO-BO-LS
Merlin Gerin - Insulated Case
MP32H-3P-3200A-EO-BO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3200A frame, includes 3200A sensor rating with 3200A rating plug, 3P, 3PH, 600V, 75kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MP63H-3P-6300A-MO-DO-LSI
MP63H-3P-6300A-MO-DO-LSI
Merlin Gerin - Insulated Case
MP63H-3P-6300A-MO-DO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 6300A frame, includes 6300A sensor rating with 6300A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MP32-3P-3200A-EO-BO-LIG
MP32-3P-3200A-EO-BO-LIG
Merlin Gerin - Insulated Case
MP32-3P-3200A-EO-BO-LIG, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3200A frame includes 3200A sensor rating with 3200A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MP30H2-3P-3000A-MO-BO-LS
MP30H2-3P-3000A-MO-BO-LS
Merlin Gerin - Insulated Case
MP30H2-3P-3000A-MO-BO-LS, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3000A frame, includes 3000A sensor rating with 3000A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MP32H-3P-3200A-MO-BO-LI
MP32H-3P-3200A-MO-BO-LI
Merlin Gerin - Insulated Case
MP32H-3P-3200A-MO-BO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3200A frame, includes 3200A sensor rating with 3200A rating plug, 3P, 3PH, 600V, 75kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MP32-3P-3200A-MO-BO-LI
MP32-3P-3200A-MO-BO-LI
Merlin Gerin - Insulated Case
MP32-3P-3200A-MO-BO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3200A frame includes 3200A sensor rating with 3200A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
KA2070TA
KA2070TA
Westinghouse - Trip Units And Programmers
KA2070TA, Westinghouse, KA Series, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 70A, 50°C, suitable for 225A- KA,HKA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price
Limited Stock
MP32H2-3P-3200A-EO-DO-LSI
MP32H2-3P-3200A-EO-DO-LSI
Merlin Gerin - Insulated Case
MP32H2-3P-3200A-EO-DO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3200A frame, includes 3200A sensor rating with 3200A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
1KES110T
1KES110T
Cutler Hammer - Rating Plug
1KES110T, Cutler Hammer, Series C, type KES, interchangeable rating plug element, rated for 110A, suitable for use with the 125A current sensor rating, to be used with Series C- KD,DK,KDB,HKD,HKDB,KDC,CKD,CHKD,KW,HKW,KWC molded case circuit breaker frame types, for use with DIGITRIP,RMS310,KES solid state electronic trip units & circuit breakers
From Get Price
Limited Stock
MP30-3P-3000A-EO-BO-LSI
MP30-3P-3000A-EO-BO-LSI
Merlin Gerin - Insulated Case
MP30-3P-3000A-EO-BO-LSI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 3000A frame includes 3000A sensor rating with 3000A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmers/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MP16-3P-800A-MO-DO-LI
MP16-3P-800A-MO-DO-LI
Merlin Gerin - Insulated Case
MP16-3P-800A-MO-DO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1600A frame with 1600A sensor rating with 800A rating plug, 3P, 3PH, 600V, 50kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
MP12H2-3P-1200A-EO-DO-LI
MP12H2-3P-1200A-EO-DO-LI
Merlin Gerin - Insulated Case
MP12H2-3P-1200A-EO-DO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 1200A frame, includes 1200A sensor rating with 1200A rating plug, 3P, 3PH, 600V, 100kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price
Limited Stock
TEPHM4
TEPHM4
General Electric - Part And Accessory
TEPHM4, General Electric, TDM Model, circuit breaker accessory, Operating Handles, rotary level handle mechanism, handle included, door-mounted, handle mounting location right, handle to device connection 5-1/8 inch to 5-13/16 inch adjustable depth shaft, NEMA 1/3R/12, suitable for use with TEB,TEC,TB1,TED,THED type molded case circuit breakers
From Get Price
Limited Stock
A4KES400T2
A4KES400T2
Cutler Hammer - Rating Plug
A4KES400T2, Cutler Hammer, Series C, type KES, interchangeable rating plug element, rated for 200-400A, suitable for use with the 400A current sensor rating, to be used with Series C- KD,DK,KDB,HKD,HKDB,KDC,CKD,CHKD molded case circuit breaker frame types, for use with DIGITRIP,RMS310,KES solid state electronic trip units & circuit breakers
From Get Price
Limited Stock
HMA2200TV
HMA2200TV
Westinghouse - Trip Units And Programmers
HMA2200TV, Westinghouse, MARK 75, type , interchangeable trip unit with LI - Long-Time and Instantaneous trip functions, rated for 200A, 50°C, suitable for 800A- MA,HMA standard, Saf-T-Vue or MARK 75 molded case circuit breaker frame types, Thermal Magnetic trip units and programmers & circuit breakers; these trip units are obsolete; however we do still stock them
From Get Price
Limited Stock
MP50H2-3P-5000A-MO-BO-LI
MP50H2-3P-5000A-MO-BO-LI
Merlin Gerin - Insulated Case
MP50H2-3P-5000A-MO-BO-LI, Merlin Gerin, insulated case circuit breaker, Masterpact, type , 5000A frame, includes 5000A sensor rating with 5000A rating plug, 3P, 3PH, 600V, 125kA@480V, accepts the following programmer/trip unit devices: STR28D, STR28DP, STR38S, STR38P, STR38ST, STR38SW, STR58U, STR58UP, STR58UT, STR58UW, STR68U, AC-PRO-MP, Solid State electronic, insulated case circuit breakers
From Get Price